SSD Drives
Division
Search SSD Drives:

AC Drives

DC Drives

Servo Drives
  -890
  -631
  -635
  -637F
  -DLD Series
  -DSD Series
  -DPD Series
  -RTS Series

Servo Motors

HMI Touch Screens

Communications

Packaged Drives

Systems Solutions

Product Manuals

For more information, contact us at:

Parker Hannifin Corp.
SSD Drives Division
9225 Forsyth Park Dr.
Charlotte, NC 28273

Phone: (704)588-3246



Click here for
SSD Drives
contact information

 

 

 

 

 

 

 


Digital Brushless Servo Drives
from 1 to 6 Ampere

Description

 

The 631 Drive is no longer provided for new applications, but has been superceded by the 638 series.

 

Advantages of migrating to the 638 include:

STO input as standard - not available on the 631
RoHS compliance
Independent input for +24Vdc supply
Can be installed on a common DC link
More fieldbus options : Profibus-DP, DeviceNet, Interbus, CANopen

 

For existing 631 users, with minimal work, existing 631 configurations (Bias and parameters) can be transfered to 638 and used on the new drive.

 

 




 

 

Internal EMC filter

Integral options

Cam profile

Electronic gearing

Speed and position control

Cut to length

Simple Set-Up and programming

Extremely compact

 

AVAILABLE OPTIONS

Operators panel IBT CanBus
Expansion module I/O CanBus
Absolute encoder CanBus
Line reactors for European market
Cables and connectors

TECHNICAL SPECIFICATIONS

Supply Power
Single Phase 220-240Vac ±10%
50-60Hz ±5%

Ambient Temperature
0-40°C

Overload
200% for 10 seconds
150% for 20 seconds
125% for 40 seconds

Protection option IP20

Inputs/Outputs

Analog Inputs
1 a 12 bit 0-±10V

Digital Inputs
(4 total, 3 configurable) 24Vdc

Digital Outputs
(2 total, configurable), 60mA max 30Vdc
Short circuit protected

INTERNATIONAL CODE

The 631 series complies to standard code when installed in accordance to manufacturers installation manual.

EN50178
(Protection Low Voltage Directive)

EN50081-1 (1992)
(emissions per unit in ambient at 230V with EMC filter)

EN50082-2 (1995)
(immune in industrial EMC environment)

EN61800-3
(Standard EMC specifics per Drive)

EN61000-3-2
(Standard harmonics with line inductors)

Complies with CE, UL and c-UL

 

Click here for "631/635/637-Series Servo Drives" PDF (82k)



© Copyright 1999-2010 Parker Hannifin Corporation
All rights reserved. Legal Information. Privacy Statement.