Technical Specifications
- Power Supply
890CS:
208–500Vac ±10%
- Inverter(DC-AC)
890CD: 320/560–705Vdc
- Converter (AC-AC)
890SD:
380–500Vac ±10% (Frames E thru K: 380–460Vac ±10%)
- Operating Temperature
0–45°C (Derate 2%/°C to 50°C max - Frame
sizes G thru K: 0–40°C)
- Maximum Humidity
85% non-condensing
- Altitude
1000m ASL (Derate 1%/100m 1000–4000m max)
- Degree of Protection
IP20:
Frame sizes B,C,D, E, F
IP00:
Frame sizes G, H, J
IP52:
Frame size K
|
|
Inputs/Outputs
- Analog Inputs:
4 total, 2 configurable
(0-10V, ±10V, 0-20mA,
4-20mA), +2 configurable (0-10V, ±10V)
- Analog Outputs:
2 configurable (0-10V, ±10V)
- Digital Inputs:
7 configurable (24V)
- Digital I/O:
2 configurable (24V)
- Relay Digital Output:
1 configurable (24V)*
*3 additional 230V rated dry
contacts (frames E-K)
|
|
International Standards
The 890 complies to standard code when installed in accordance
to manufacturers installation manual:
- Conforms to EC Directive 89/336/EEC in compliance
with standard:
- EN61800-3 (Environment 2)
- Conforms to EC Directive 73/23/EEC in compliance with standard:
- EN50178 (Low Voltage)
- Complies with UL508C safety standard
- Complies with CE, UL e c-UL
|

AC890 System Drives are modular AC drive units that
can be combined to form a complete multi-section drive system,
saving space, reducing wiring, and providing unmatched system performance.
The AC890 can control everything from induction motors
to servo motors. AC890 provides V/F, sensorless vector, closed-loop
flux vector and servo position control; from simple AC motor control
sections to more demanding sections. The AC890 comes in a wide
variety of sizes and ratings and input and output types, making
it the right solution for virtually any motion control project.
5-Mode Frequency Converter:
- V/F, Sensorless Vector, Flux Vector, Servo Drive, Line Regenerative
(AFE)
- Built-in EMC Filters
- 2 Performance Levels (Advanced and High Performance)
- COMMS Options Available
COMMON BUS Drives (CD) are individual motor
output sections that easily connect to a COMMON BUS Supply
(CS) with a unique, easy-to-install DC bus
bar system (SSD Rail).
COMMON BUS Made Easy!
DC bus terminals are located at top of each drive section.
Easy to use screw clamps secure the high power bus bars.
This low cost, compact design significantly reduces wiring
in
common bus systems, saving time and material cost.
COMMON BUS Drives (CD)
- Have internal DC fuses
- Need no reactors
- Provide access to all feedback and networking options
STANDALONE Drives (SD)
The AC890 Standalone Drives are complete AC-input-to-AC motor output
controller with power input and output terminals, and access
to all feedback and networking options.

890CD/890SD Control Board
- Programming Port USB
- Torque and Speed Analog Outputs
- Health Contact
- 24Vdc Control Supply - Programming without Power Supply
- Digital I/O
- Motor Thermistor Input
- Running and Zero Speed Signal Output
Performance Levels
AC890 frequency converters offer the level of performance that
best suits your application needs. With 2 different performance
levels, AC890 system allows the maximum flexibility of use.
- Advanced Performance
Basic LINK VM function blocks: math functions, Boolean logic,
timers, counters, One shots, threshold comparators, latches,
plus: motion control firmware with added position loop, motion
control function blocks, move incremental, move absolute, move
home, line drive master ramp and section control, winder blocks
(SPW, CPW), full function PID, state machine, and others.
- High
Performance
All Advanced Performance features, plus: Library of pre-engineered
application specific LINK VM function blocks such as:
shaftless printing, cut-to-length, precision winding, traversing,
and others.
Shaftless Registration Control Solutions for Printing
Mechanical line shafts for printing are easily replaced with individual
AC890 drives, capable of precise synchronization and printing
registration adjustment to each section, guaranteeing perfect
alignment of each color. AC890 High Performance Level features
a library of pre-engineered application specific LINK VM function
blocks, including shaftless printing, cut-to-length, precision
winding, traversing, and others.
FireWire protocol (IEEE1394) ensures data synchronization for
the printing register control.
- 125µS Cycle time
- Time Synchronization
- Deterministic Network

Active Front End: Line Regenerative Systems
Common Bus Drive sections can also be configured as Active-Front-End
Input Sections, providing true lineregenerative 4-quadrant control
with no harmonics and 1.0 power factor.
Requirements
- Pre-charging Circuit
- LCL Filter
Performance
- Fully Bidirectional Power Flow
- Overload 150% for 60 secs
- Sinusoidal Input Current
- Complies with IEEE 519
Larger AC890 systems can be matched with separate higher power
Active Front End units. Multiple rows of AC890 Common Bus Drives
are bridged together using Common Bus Adapter modules.
890 Series CS/CD
890 Series CS/CD units provide a common bus solution
for multi-section drive applications. Multiple 890 Series CD
Common Bus Drive inverter sections can be combined with
a single 890 Series CS Common Bus supply unit, achieving
substantial space savings and peripheral component
savings within the enclosure. Additional 890 Series CS
supply units may be paralleled to provide greater DC bus
supply amperage.
How to Pick a CS
- Select the 890CD (common-bus drives), one for
each section.
- Select
the 890CS (common-bus supply) module by adding the HP (or
currents) of all the CD drives.
- Select a reactor and braking resistor kit
- Order the common bus
bar and exhaust duct kit from the options section
890CS Power Supply Unit
- up to 162A
- Power Supply 208–500VAC
- Built-in Dynamic Braking Unit
- DC BUS Supply Output
- Diagnostic Operator Panel
890CS Control Board
- 24Vdc Supply Control
- HMI Interface Connection
- Three-phase Supply Selector
- Configurable Analog Output
- Prewarning Output
- Alarm Output
| AC890 Common Bus Supplies
used with 230 - 500Vac (+/-10%) 3 phases |
| Part Number |
Frame |
HP@
460Vac |
HP@
230Vac |
Input Amps |
| 890CS/5/0032B/B/00/N/EN |
B |
25 |
10 |
32 |
| 890CS/5/0054B/B/00/N/EN |
45 |
20 |
54 |
| 890CS/5/0108D/B/00/N/EN |
D |
75 |
40 |
108 |
| 890CS/5/0162D/B/00/N/EN |
135 |
60 |
162 |
890CD Inverters
from 1.5 to 180A
- 320, 650, 705VDC Power Supply
- Standard Equipped Keypad
- Common Options with 890SD
- COMMS Options Available
| AC890 Common Bus Drives
208 - 230Vac (+/-10%) |
| Part Number |
Frame |
HP@
230Vac |
Output Amps@
230Vac |
| 890CD/2/0003B/N/00/A/US |
B |
0.75 |
3 |
| 890CD/2/0005B/N/00/A/US |
1.5 |
5.5 |
| 890CD/2/0007B/N/00/A/US |
2 |
7 |
| 890CD/2/0011B/N/00/A/US |
3 |
11 |
| 890CD/2/0016B/N/00/A/US |
5 |
16.5 |
| 890CD/2/0024C/N/00/A/US |
C |
7.5 |
24 |
| 890CD/2/0030C/N/00/A/US |
10 |
30 |
| AC890 Common Bus Drives
380 - 500Vac (+/-10%) |
| Part Number |
Frame |
HP@
460Vac |
Output Amps@
460Vac |
| 890CD/5/0002B/N/00/A/US |
B |
1 |
2 |
| 890CD/5/0003B/N/00/A/US |
1.5 |
3.5 |
| 890CD/5/0004B/N/00/A/US |
2 |
4.5 |
| 890CD/5/0006B/N/00/A/US |
3 |
5 |
| 890CD/5/0010B/N/00/A/US |
5 |
8 |
| 890CD/5/0012B/N/00/A/US |
7.5 |
12 |
| 890CD/5/0016B/N/00/A/US |
10 |
14 |
| 890CD/5/0024C/N/00/A/US |
C |
15 |
24 |
| 890CD/5/0030C/N/00/A/US |
20 |
27 |
| 890CD/5/0039D/N/00/A/US |
D |
25 |
35 |
| 890CD/5/0045D/N/00/A/US |
30 |
40 |
| 890CD/5/0059D/N/00/A/US |
40 |
52 |
| 890CD/4/0073E/N/00/A/US |
E |
50 |
73 |
| 890CD/4/0087E/N/00/A/US |
60 |
87 |
| 890CD/4/0105F/N/1F/A/US |
F |
75 |
100 |
| 890CD/4/0145F/N/1F/A/US |
100 |
130 |
| 890CD/4/0156F/N/1F/A/US |
125 |
156 |
| 890CD/4/0180F/N/1F/A/US |
150 |
180 |
890SD Series
from 1.5 to 1681A
890SD Series (Stand Alone) frequency converters
are independent units that can be powered either
with mains three phase voltage or via DC bus.
890SD Series comes in a wide choice of sizes,
suitable for every type of application, from small
industrial machines to high-powered large plants
(e.g. rolling mills, paper mills). They are also ideal
for applications where single units are machine mounted
(e.g. printing units).
- Direct Mains Supply or Via DCBUS
- Built-in Dynamic Braking Unit
- Standard with Keypad
- Common Options with 890CD
- COMMS Options Available
| AC890 Stand-alone Drives 208-240Vac (+/-10%) Input 3-phase |
| Part Number |
Frame |
HP@
230Vac |
Output Amps@
230Vac |
| 890SD/2/0003B/B/00/A/US |
B |
0.75 |
3 |
| 890SD/2/0005B/B/00/A/US |
1.5 |
5.5 |
| 890SD/2/0007B/B/00/A/US |
2 |
7 |
| 890SD/2/0011B/B/00/A/US |
3 |
11 |
| 890SD/2/0016B/B/00/A/US |
5 |
16.5 |
| 890SD/2/0024C/B/00/A/US |
C |
7.5 |
24 |
| 890SD/2/0030C/B/00/A/US |
10 |
30 |
Note: The 890 comes in two performance level configurations,
Advanced and High. The part #’s shown above 890SD/x/xxxxx/x/xx/A/xx
are for Advanced models. For High Performance models, replace the
Performance Level field designator with an H.
AC890 Stand-alone Drives
380 -500Vac (+/-10%) Input -3 Phase: Frames B thru D
380 -460Vac (+/-10%) Input -3 Phase: Frames E and Higher |
| Part Number |
Frame |
HP@
460Vac |
Output Amps@
460Vac |
| 890SD/5/0002B/B/00/A/US |
B |
1 |
2 |
| 890SD/5/0003B/B/00/A/US |
1.5 |
3.5 |
| 890SD/5/0004B/B/00/A/US |
2 |
4.5 |
| 890SD/5/0006B/B/00/A/US |
3 |
5 |
| 890SD/5/0010B/B/00/A/US |
5 |
8 |
| 890SD/5/0012B/B/00/A/US |
7.5 |
12 |
| 890SD/5/0016B/B/00/A/US |
10 |
14 |
| 890SD/5/0024C/B/00/A/US |
C |
15 |
24 |
| 890SD/5/0030C/B/00/A/US |
20 |
27 |
| 890SD/5/0039D/B/00/A/US |
D |
25 |
35 |
| 890SD/5/0045D/B/00/A/US |
30 |
40 |
| 890SD/5/0059D/B/00/A/US |
40 |
52 |
| 890SD/4/0073E/B/00/A/US |
E |
50 |
73 |
| 890SD/4/0087E/B/00/A/US |
60 |
87 |
| 890SD/4/0105F/B/1F/A/US |
F |
75 |
100 |
| 890SD/4/0145F/B/1F/A/US |
100 |
130 |
| 890SD/4/0156F/B/1F/A/US |
125 |
156 |
| 890SD/4/0180F/B/1F/A/US |
150 |
180 |
| 890SD/4/0216G/ * /1F/A/US |
G |
175 |
216 |
| 890SD/4/0250G/ * /1F/A/US |
200 |
250 |
| 890SD/4/0316G/ * /1F/A/US |
250 |
316 |
| 890SD/4/0361G/ * /1F/A/US |
300 |
361 |
| 890SD/4/0420H/ * /1F/A/US |
H |
350 |
420 |
| 890SD/4/0480H/ * /1F/A/US |
400 |
480 |
| 890SD/4/0520H/ * /1F/A/US |
450 |
520 |
| 890SD/5/0590J/ * /1F/A/US |
J |
500 |
590 |
| 890SD/5/0685K/ * /1F/A/US |
K(2xG) |
600 |
685 |
| 890SD/5/0798K/ * /1F/A/US |
K(2xH) |
700 |
798 |
| 890SD/5/0988K/ * /1F/A/US |
K(2xH) |
800 |
988 |
| 890SD/5/1028K/ * /1F/A/US |
K(3xG) |
900 |
1028 |
| 890SD/5/1120K/ * /1F/A/US |
K(2xJ) |
1000 |
1120 |
| 890SD/5/1197K/ * /1F/A/US |
K(3xH) |
1000 |
1197 |
| 890SD/5/1482K/ * /1F/A/US |
K(3xH) |
1300 |
1482 |
| 890SD/5/1681K/ * /1F/A/US |
K(3xJ) |
1500 |
1681 |
* The Braking switch is optional on these models–B is
braking, N is no brake..
Note: The 890 comes in two performance level configurations,
Advanced and High. The part #’s shown above 890SD/x/xxxxx/x/xx/A/xx
are for Advanced models. For High Performance models, replace the
Performance Level field designator with an H.

| Dimensions |
| Frame |
H |
W |
D |
| 890 Frame B |
17.1 (433) |
2.9 (72) |
10.2 (258) |
| 890 Frame C |
4.6 (116) |
| 890 Frame D |
6.3 (160) |
| 890 Frame E |
26.3 (668) |
10.1 (257) |
12.3 (312) |
| 890 Frame F |
28.3 (720) |
13.4 (355) |
| 890 Frame G |
41.0 (1042) |
17.9 (456) |
18.3 (465) |
| 890 Frame H |
46.3 (1177) |
22.5 (572) |
| 890 Frame J |
50.7 (1.288) |
26.6 (675) |
| 890 Frame K |
For K Frame Dimensions- Consult Factory |
Cables and Connectors
| Cables |
| Part Number |
Description |
| CM471050 |
890 USB Programming Cable |
| 8905/FWCBL200/00 |
200 mm FireWire Cable (B Frame to a B, C, and D Frame) |
| 8905/FWCBL280/00 |
280 mm FireWire Cable (C, D Frame to a B, C, and D Frame) |
| 8905/FWCBL1000/00 |
1000 mm FireWire Cable (Rack to Rack) |
| 8905/FWCBL4500/00 |
4500 mm FireWire Cable (Rack to Enclosure) |
| Bus Bar System |
| Part Number |
Description |
| BH465850 |
1 m DC SSD Rail/Bus Bar 140A (UL) |
| BC465938U200 |
200 mm Insulator for DC Bus Bars |
| BA469216 |
Grounding Bus Bar 1m (CS/CD only) |
| Assembly Kit |
| Part Number |
Description |
| BA465900 |
Clips for Fitting on DIN rail |
| BA465887 |
Control Cable Support |
| BA465888 |
Supply Cable Support |
| LA471585 |
I/O Terminal Interface Module |
| CM471585U001, U002, U003 |
Drive to module cable for LA471585 (1 meter, 2 meter, 3 meter) |
| CM471592 |
Extended module to module cable for LA471585 (2 meter) |
| 8905/DUCTKIT/190 |
Duct Kit (1 m Exhaust Duct for Frames B, C, and D + 1 Fan
Kit Rated at 190 CFM) |
Options
| Feedback |
| Part Number |
Description |
| 8902/E1/00/FF |
Abs Sin/Cos (Endat 2.1) |
| 8902/EQ/00/FF |
Encoder (Incremental Quadrature) |
| 8902/M1/00/FF |
Abs Sin/Cos (Endat 2.1) w.Registration |
| 8902/RE/00/FF |
Resolver |
| Comms Options |
| Part Number |
Description |
| 8903/FA/00/FF |
FireWire 1394a Communication Module |
| 8903/DN/00/FF |
DeviceNet Communication Module |
| 8903/PB/00/FF |
ProfiBus Communication Module |
| 8903/CN/00/FF |
ControlNet Communication Module |
| 8903/CB/00/FF |
CanOpen Communication Module |
| 8903/IP/00/FF |
Ethernet/IP Communication Module |
| 8903/IM/00/FF |
Ethernet Modbus/TCPCommunication Module |
| 8903/PN/00/FF |
Ethernet PROFINET Module |
| Keypads |
| Part Number |
Description |
| 6901/00/G | Alphanumeric Multilingual Keypad |
| 6502/00/G |
Remote Mounting Kit for 6901 Keypad Including 3m Cable |
| 6911 |
Enhanced alphanumeric keypad with Rotary Selector |
| Firewire Repeaters |
| Part Number |
Description |
| LA471480 |
Firewire Repeater 100Mb/100ft |
Click
here for "AC890" PDF (3.3mb)

Click