TECHNICAL SPECIFICATION
Power Configuration
590+ Four Quadrant Regenerative; 2 Fully Controlled Three Phase Thyristor
Bridges 591+ Two Quadrant Non-Regenerative; 1 Fully Controlled Three
Phase Thyristor Bridge Thyristor Controlled Variable Field Supply
Armature Current Ratings (Adc)
| Frame 1 |
15, 23A |
| Frame 2 |
40, 70, 110, 165A |
| Frame 3 |
180, 270A |
| Frame 4 |
380, 500, 725, 830A |
| Frame 5 |
1580A |
| Frame H |
1200, 1700, 2200, 2700A |
DRV Version available Frame 1 and 2
Overload
15-450A; 200% for 10 seconds 150% for 30 seconds =700A;
Various overload options available
Armature Voltage
Varmature = Vac x 1.15
AC Supply Voltage (Vac) 50/60Hz
220-500V (±10%) Frame 1-5 110-220V (±10%) option Frame 1-5
500-600 (±10%) option Frame 4-5 500-690V (±10%) Frame H
Field Current
4A Frame 1 30A Frame 4 and 5 10A Frame 2 and 3 60A Frame H
Field Voltage
Vfield = Vac x 0.82
Ambient
Temperature 0-40șC (=1200A ratings) 0-45șC (15-165A ratings) Derate 1%/șC for higher
0-35șC (180-270A ratings) ambients to 55șC max
Altitude
500m ASL Derate 1%/200m above 500m to 5000m max
|